Product Overview
An Indoor Voltage Transformer (Indoor VT)—commonly specified as an Indoor Potential Transformer (PT) or cast-resin voltage transformer—is an instrument transformer designed to convert medium-voltage primary signals (such as a standard 11kV voltage transformer configuration) into standardized low-voltage secondary signals for electrical measurement, energy metering, and protection systems.
Installed in indoor medium-voltage switchgear, metal-enclosed distribution equipment, and other power distribution assemblies, indoor voltage transformers provide electrically isolated voltage signals to measuring instruments, energy meters, and protective relays.
Depending on the system voltage, insulation requirements, and switchgear configuration, Indoor VTs can be specified with different primary voltage ratings, secondary voltage ratios, accuracy classes, rated outputs, and mounting arrangements.
-
JDZX9-35 Indoor Single-phase Voltage TransformerThe voltage transformers are in accordance with GB20840.3-2013 and IEC60044-2 standards
Rated insulation level: 40.5/95/185kV
Pollution class: class Ⅱ
Rated frequency:... -
JSZY16-35R Voltage TransformerThe JSZY16-35R voltage transformer manufactured by Wenzhou Best Imp. & Exp. Co., Ltd is specifically designed for outdoor switchgear. Featuring fuse protection for the primary winding, this...
-
JDZX11-35 Indoor Voltage TransformerJDZX11-35R voltage transformer is a 35kV voltage transformer, belonging to single-phase cast-in-place indoor voltage transformer and dry-type with fuse voltage transformer. It is suitable for...
-
JSZVR-10W Indoor Three-phase Voltage TransformerThe voltage transformers are in accordance with GB20840.3-2013 and IEC60044-2 standards
Rated insulation level: 12/42/75, 7.2/32/60kV
Rated frequency: 50Hz or 60Hz -
JDZX18-10R1 Indoor Single-phase Voltage TransformerThe voltage transformers are in accordance with GB20840.3-2013 and IEC60044-2 standards
Rated insulation level: 12/42/75, 7.2/32/60kV
Rated frequency: 50Hz or 60Hz -
JDZ8-10R Indoor Single-phase Voltage TransformerThe voltage transformers are in accordance with GB20840.3-2013 and IEC60044-2 standards
Rated insulation level: 12/42/75, 7.2/32/60kV
Rated frequency: 50Hz or 60Hz -
JDZ(J)-10Q Indoor Single-phase Voltage TransformerThe voltage transformers are in accordance with GB20840.3-2013 and IEC60044-2 standards
Rated insulation level: 12/42/75, 7.2/32/60kV
Rated frequency: 50Hz or 60Hz -
JDZC-10 Indoor Single-phase Voltage TransformerThe voltage transformers are in accordance with GB20840.3-2013 and IEC60044-2 standards
Rated insulation level: 12/42/75, 7.2/32/60kV
Rated frequency: 50Hz or 60Hz -
JDZX10-10 Indoor Single-phase Voltage TransformerThe voltage transformers are in accordance with GB20840.3-2013 and IEC60044-2 standards
Rated insulation level: 12/42/75, 7.2/32/60kV
Rated frequency: 50Hz or 60Hz -
JDZX9-10Q Indoor Single-phase Voltage TransformerThe voltage transformers are in accordance with GB20840.3-2013 and IEC60044-2 standards
Rated insulation level: 12/42/75, 7.2/32/60kV
Rated frequency: 50Hz or 60Hz
Technical Specifications
|
Parameter |
Specification / Available Options |
|
Product Type |
Indoor Voltage Transformer (VT / PT) / Cast-Resin VT |
|
Application |
Medium-voltage indoor switchgear and power distribution systems |
|
Highest Voltage for Equipment (Um) |
Model-dependent; confirm available 12 kV, 24 kV, and 40.5 kV classes |
|
Rated Primary Voltage |
According to system voltage and product design |
|
Rated Secondary Voltage |
100 / √3 V, 110 / √3 V, 100 V, 110 V, or other specified ratios |
|
Accuracy Class |
Metering classes such as 0.2 and 0.2S; protection classes such as 3P |
|
Rated Output (Burden) |
Specified according to winding configuration and accuracy requirements |
|
Secondary Windings |
Single or multiple secondary windings, subject to design |
|
Insulation Level |
Power-frequency withstand voltage and lightning impulse withstand voltage |
|
Rated Frequency |
50 Hz / 60 Hz, subject to model |
|
Thermal Limiting Output |
According to the manufacturer's confirmed design data |
|
Insulation Material |
Cycloaliphatic cast-resin insulation |
|
Applicable Standards |
IEC 61869-1 and IEC 61869-3, where applicable |
|
Other Standards |
IEEE C57.13, subject to product design and verified compliance |
Construction & Materials
Indoor voltage transformers generally consist of an electromagnetic core, primary and secondary windings, an insulation system, and electrical connection components. Their construction is selected according to the required voltage ratio, insulation level, accuracy class, and installation arrangement.
Primary Insulation
Cast-resin insulation is used in applicable indoor voltage transformer designs to provide electrical insulation between windings and between energized components and grounded parts. The resin system, casting process, insulation geometry, and creepage distance are determined according to the product's rated voltage and insulation requirements.
Magnetic Core
The magnetic core provides the magnetic circuit required for voltage transformation. Laminated electrical steel (CRGO) is used to form the core. Core material, lamination structure, and assembly processes are selected according to the required excitation characteristics and transformer performance.
Primary and Secondary Windings
The primary and secondary windings are designed according to the specified voltage ratio, rated output, and accuracy requirements. Conductor material, winding arrangement, and insulation structure depend on the electrical and thermal design of the transformer. Multiple secondary windings may be specified for separate metering and protection circuits.
Terminals and Mounting Components
Primary and secondary terminals are arranged according to electrical connection requirements and switchgear installation configurations. Terminal materials, surface treatments, grounding connections, mounting dimensions, and connection positions should be confirmed against technical drawings.
Selecting an indoor voltage transformer requires checking its electrical ratings, measurement requirements, secondary circuit configuration, and mechanical installation conditions.
Voltage Rating and Insulation Coordination
The transformer's highest voltage for equipment (Um), rated primary voltage, and insulation withstand levels should be compatible with the intended power distribution system and switchgear design, covering nominal system voltage, power-frequency withstand voltage, and lightning impulse withstand voltage.
Accuracy Class and Rated Burden
For metering applications: Select class 0.2 or 0.2S for revenue metering across extended load ranges.
For protection applications: Select the protection accuracy class (e.g., 3P) according to relay requirements.
Burden calculation: Consider connected meter/relay burdens, secondary cable length, conductor resistance, and the number of connected devices against the rated output.
Secondary Winding Configuration
Single secondary winding for standard measurement or protection.
Dual secondary windings for separate metering and protection circuits.
Other specified secondary arrangements according to system design.
Mechanical Dimensions and Switchgear Compatibility
Verify overall dimensions, installation height, mounting base bolt-hole positions, terminal arrangements, phase-to-phase clearances, and compartment layouts.
Note for Retrofit Projects: For legacy switchgear (such as KYN28 frameworks), original equipment drawings and actual installation dimensions must be checked. A matching switchgear series name alone does not establish direct interchangeability.

Manufacturing & Quality Control
The manufacturing and quality control process for indoor voltage transformers involves strict control of core and winding assemblies, insulation components, electrical connections, and final product verification.
Core and Winding Assembly
Assemblies are prepared according to the specified voltage ratio, winding arrangement, and electrical design, with rigorous checks on core materials, winding alignment, and terminal connections.
Resin Insulation and Casting
For cast-resin designs, the insulation process involves applying the specified resin insulation system under strict casting conditions, curing parameters, and visual verification to eliminate voids.
Routine Electrical Testing
Routine testing verifies power-frequency withstand voltage, induced voltage withstand, voltage ratio and polarity, accuracy and phase displacement, and winding resistance.
Partial Discharge Testing
Partial discharge testing is conducted according to standard requirements, ensuring strict limits (such as ≤ 10 pC at specified voltages) to guarantee long-term insulation integrity. Test records are available upon request.

Indoor voltage transformers are used in medium-voltage electrical distribution and switchgear systems where isolated voltage signals are required for measurement, metering, and protection. Typical application areas include:
Indoor Metal-Enclosed Switchgear (AIS/GIS): Provides stable voltage signals for internal measurement and protection circuits.
Medium-Voltage Distribution Panels: Supports voltage monitoring and electrical measurement in distribution assemblies.
Ring Main Units (RMUs): Used in compatible configurations for compact voltage measurement and related protection functions.
Industrial Power Distribution Systems: Supplies secondary voltage signals to local electrical monitoring instruments and protective relays.
Switchgear Retrofit & Replacement Projects: Evaluated for replacement applications based on precise electrical ratings and mechanical dimensions.
Frequently Asked Questions

Request a Technical Proposal & Quote
To receive a product quotation and technical evaluation from our engineering team, please provide the following parameters:
Electrical System Information:
System nominal voltage and Highest voltage for equipment (Um).
Rated frequency (50 Hz or 60 Hz).
Voltage Ratio:
Required primary voltage and secondary voltage.
Accuracy and Rated Output:
Required metering and protection accuracy classes.
Rated output (VA) for each secondary winding.
Winding Configuration:
Number of secondary windings and specific circuit allocations.
Mechanical and Installation Requirements:
Switchgear manufacturer and model / Existing transformer model.
Mounting dimensions, primary connection arrangement, and available dimensional drawings.
Documentation Requirements:
Technical data sheets, dimensional drawings, routine test reports, or type test reports.
With abundant experience, Wenzhou Best Imp. & Exp. is one of the most professional indoor voltage transformer manufacturers and suppliers in China. Please feel free to buy durable indoor voltage transformer made in China here from our factory. Quality products and good service are available.
indoor voltage transformer, JDZX18 10R1 Indoor Single phase Voltage Transformer, JSZVR 10W Indoor Three phase Voltage Transformer