Product Overview

 

An Indoor Voltage Transformer (Indoor VT)—commonly specified as an Indoor Potential Transformer (PT) or cast-resin voltage transformer—is an instrument transformer designed to convert medium-voltage primary signals (such as a standard 11kV voltage transformer configuration) into standardized low-voltage secondary signals for electrical measurement, energy metering, and protection systems.
Installed in indoor medium-voltage switchgear, metal-enclosed distribution equipment, and other power distribution assemblies, indoor voltage transformers provide electrically isolated voltage signals to measuring instruments, energy meters, and protective relays.
Depending on the system voltage, insulation requirements, and switchgear configuration, Indoor VTs can be specified with different primary voltage ratings, secondary voltage ratios, accuracy classes, rated outputs, and mounting arrangements.

 

 
 
Technical Specifications

 

Parameter

Specification / Available Options

Product Type

Indoor Voltage Transformer (VT / PT) / Cast-Resin VT

Application

Medium-voltage indoor switchgear and power distribution systems

Highest Voltage for Equipment (Um)

Model-dependent; confirm available 12 kV, 24 kV, and 40.5 kV classes

Rated Primary Voltage

According to system voltage and product design

Rated Secondary Voltage

100 / √3 V, 110 / √3 V, 100 V, 110 V, or other specified ratios

Accuracy Class

Metering classes such as 0.2 and 0.2S; protection classes such as 3P

Rated Output (Burden)

Specified according to winding configuration and accuracy requirements

Secondary Windings

Single or multiple secondary windings, subject to design

Insulation Level

Power-frequency withstand voltage and lightning impulse withstand voltage

Rated Frequency

50 Hz / 60 Hz, subject to model

Thermal Limiting Output

According to the manufacturer's confirmed design data

Insulation Material

Cycloaliphatic cast-resin insulation

Applicable Standards

IEC 61869-1 and IEC 61869-3, where applicable

Other Standards

IEEE C57.13, subject to product design and verified compliance

 
Construction & Materials
 

Indoor voltage transformers generally consist of an electromagnetic core, primary and secondary windings, an insulation system, and electrical connection components. Their construction is selected according to the required voltage ratio, insulation level, accuracy class, and installation arrangement.

01/

Primary Insulation
Cast-resin insulation is used in applicable indoor voltage transformer designs to provide electrical insulation between windings and between energized components and grounded parts. The resin system, casting process, insulation geometry, and creepage distance are determined according to the product's rated voltage and insulation requirements.

02/

Magnetic Core
The magnetic core provides the magnetic circuit required for voltage transformation. Laminated electrical steel (CRGO) is used to form the core. Core material, lamination structure, and assembly processes are selected according to the required excitation characteristics and transformer performance.

03/

Primary and Secondary Windings
The primary and secondary windings are designed according to the specified voltage ratio, rated output, and accuracy requirements. Conductor material, winding arrangement, and insulation structure depend on the electrical and thermal design of the transformer. Multiple secondary windings may be specified for separate metering and protection circuits.

04/

Terminals and Mounting Components
Primary and secondary terminals are arranged according to electrical connection requirements and switchgear installation configurations. Terminal materials, surface treatments, grounding connections, mounting dimensions, and connection positions should be confirmed against technical drawings.

 

 

Technical Selection & Switchgear Compatibility

Selecting an indoor voltage transformer requires checking its electrical ratings, measurement requirements, secondary circuit configuration, and mechanical installation conditions.
Voltage Rating and Insulation Coordination
The transformer's highest voltage for equipment (Um), rated primary voltage, and insulation withstand levels should be compatible with the intended power distribution system and switchgear design, covering nominal system voltage, power-frequency withstand voltage, and lightning impulse withstand voltage.
Accuracy Class and Rated Burden
For metering applications: Select class 0.2 or 0.2S for revenue metering across extended load ranges.
For protection applications: Select the protection accuracy class (e.g., 3P) according to relay requirements.
Burden calculation: Consider connected meter/relay burdens, secondary cable length, conductor resistance, and the number of connected devices against the rated output.
Secondary Winding Configuration
Single secondary winding for standard measurement or protection.
Dual secondary windings for separate metering and protection circuits.
Other specified secondary arrangements according to system design.
Mechanical Dimensions and Switchgear Compatibility
Verify overall dimensions, installation height, mounting base bolt-hole positions, terminal arrangements, phase-to-phase clearances, and compartment layouts.
Note for Retrofit Projects: For legacy switchgear (such as KYN28 frameworks), original equipment drawings and actual installation dimensions must be checked. A matching switchgear series name alone does not establish direct interchangeability.

JDZX11-35 Indoor Voltage Transformer manufacturers

 

Manufacturing & Quality Control

The manufacturing and quality control process for indoor voltage transformers involves strict control of core and winding assemblies, insulation components, electrical connections, and final product verification.

Core and Winding Assembly

Assemblies are prepared according to the specified voltage ratio, winding arrangement, and electrical design, with rigorous checks on core materials, winding alignment, and terminal connections.

Resin Insulation and Casting

For cast-resin designs, the insulation process involves applying the specified resin insulation system under strict casting conditions, curing parameters, and visual verification to eliminate voids.

Routine Electrical Testing

Routine testing verifies power-frequency withstand voltage, induced voltage withstand, voltage ratio and polarity, accuracy and phase displacement, and winding resistance.

Partial Discharge Testing

Partial discharge testing is conducted according to standard requirements, ensuring strict limits (such as ≤ 10 pC at specified voltages) to guarantee long-term insulation integrity. Test records are available upon request.

 

JDZX9-35 Indoor Single-phase Voltage Transformer

 

Applications

Indoor voltage transformers are used in medium-voltage electrical distribution and switchgear systems where isolated voltage signals are required for measurement, metering, and protection. Typical application areas include:

Indoor Metal-Enclosed Switchgear (AIS/GIS): Provides stable voltage signals for internal measurement and protection circuits.

Medium-Voltage Distribution Panels: Supports voltage monitoring and electrical measurement in distribution assemblies.

Ring Main Units (RMUs): Used in compatible configurations for compact voltage measurement and related protection functions.

Industrial Power Distribution Systems: Supplies secondary voltage signals to local electrical monitoring instruments and protective relays.

Switchgear Retrofit & Replacement Projects: Evaluated for replacement applications based on precise electrical ratings and mechanical dimensions.

 

 

Frequently Asked Questions

 

 

Q: What voltage ratings are available for indoor voltage transformers?

A: Available voltage ratings depend on the product series and design, commonly covering 12 kV, 24 kV, and 40.5 kV classes. Selection should consider the rated primary voltage, highest voltage for equipment (Um), and required insulation levels.

Q: Can indoor voltage transformers be supplied with multiple secondary windings?

A: Yes. Multiple secondary windings are available depending on the product design, allowing separate windings to be specified for metering and protection circuits with independent accuracy classes and rated outputs.

Q: Can indoor VTs be customized for existing switchgear?

A: Customization is evaluated for replacement and retrofit projects. Relevant information required includes the original transformer model, switchgear type, mounting dimensions, primary connection arrangement, and secondary terminal configuration.

Q: What inspection and test documents can be supplied?

A: Available documentation includes routine test reports, technical data sheets, dimensional drawings, and applicable type test reports. Specific document availability should be confirmed when submitting your inquiry.

Q: How do I select the correct accuracy class and rated burden?

A: Selection depends on whether the transformer is used for metering (e.g., Class 0.2S) or protection (e.g., Class 3P), alongside connected equipment requirements and secondary cable lead resistance.

Q: What information is required for a formal quotation?

A: Please provide your system voltage, rated primary and secondary voltages, required accuracy classes, rated burden, winding configuration, switchgear model, and installation dimensions.

 

modular-1
Request a Technical Proposal & Quote

To receive a product quotation and technical evaluation from our engineering team, please provide the following parameters:

Electrical System Information:

System nominal voltage and Highest voltage for equipment (Um).

Rated frequency (50 Hz or 60 Hz).

Voltage Ratio:

Required primary voltage and secondary voltage.

Accuracy and Rated Output:

Required metering and protection accuracy classes.

Rated output (VA) for each secondary winding.

Winding Configuration:

Number of secondary windings and specific circuit allocations.

Mechanical and Installation Requirements:

Switchgear manufacturer and model / Existing transformer model.

Mounting dimensions, primary connection arrangement, and available dimensional drawings.

Documentation Requirements:

Technical data sheets, dimensional drawings, routine test reports, or type test reports.

With abundant experience, Wenzhou Best Imp. & Exp. is one of the most professional indoor voltage transformer manufacturers and suppliers in China. Please feel free to buy durable indoor voltage transformer made in China here from our factory. Quality products and good service are available.

indoor voltage transformer, JDZX18 10R1 Indoor Single phase Voltage Transformer, JSZVR 10W Indoor Three phase Voltage Transformer
Send Inquiry
Send Inquiry