Product Overview

 

An Outdoor Voltage Transformer (VT), also designated as an Outdoor Potential Transformer (PT), is a high-voltage electromagnetic instrument transformer engineered to step down primary transmission and distribution line potentials into safe, standardized secondary signals (100V, 110V, or 120V) for revenue metering, voltage monitoring, instrumentation, and protective relaying schemes.
Built for uncompromised outdoor switchyard performance, outdoor VTs provide vital electrical isolation between high-voltage lines and low-voltage control infrastructure.

 

 
 
Construction & Working Principle

Operating on the fundamental principle of electromagnetic induction, the primary winding connects in parallel across the high-voltage conductor, while the secondary winding delivers a proportional, phase-aligned output signal to connected control devices.

 

Primary Winding: Wound with oxygen-free copper and engineered to withstand continuous thermal currents and transient overvoltage spikes.

 

Secondary Windings: Modular winding configurations supporting simultaneous revenue metering, system protection, and residual voltage (broken-delta) monitoring.

Magnetic Core

Assembled from high-permeability cold-rolled grain-oriented silicon steel (CRGO) using step-lap mitred joints to minimize core loss and maintain high linearity during fault conditions.

Insulation Structure

Hydrophobic Cycloaliphatic Epoxy Resin (HPWR) vacuum-cast via Automated Pressure Gelation (APG) to eliminate internal micro-voids and prevent tracking under intense solar UV exposure.

External Enclosure

Structural steel mounting bases finished with hot-dip galvanizing (min. 85 um) and marine-grade aluminum secondary junction boxes (IP55/IP66).

 

Technical Specifications

 

Technical Parameter

Standard Specification

Product Type

Outdoor Voltage Transformer (VT / PT)

Equipment Highest Voltage (Um)

12 kV / 24 kV / 36 kV (Custom higher ratings available)

Rated Primary Voltage

10 kV to 33 kV

Rated Secondary Voltage

100V, 110V, 120V (Dual-ratio configurations supported)

Secondary Winding Arrangement

Multi-tap configurable (Metering, Protection, Residual Voltage)

Metering Accuracy Class

0.2S, 0.5

Protection Accuracy Class

3P, 6P

Rated Burden

15 VA to 150 VA per winding

Rated Voltage Factor

1.2 Continuous, 1.9 for 30s (or 8h per network grounding design)

Power-Frequency Withstand Voltage

28 kV to 70 kV (1 min)

Lightning Impulse Withstand Voltage

75 kV to 170 kV (1.2/50 us wave)

Minimum Creepage Distance

>= 25 mm/kV up to 31 mm/kV (IEC 60815 Class III / IV)

Ambient Operating Temperature

-40 deg C to +55 deg C

Design & Test Standards

IEC 61869-1, IEC 61869-3, IEEE Std C57.13

Secondary Winding Configurations

 

 

Metering Winding

Dedicated to revenue meters and billing instruments. High-precision 0.2S classes guarantee measurement accuracy even under low partial loads (25% to 100% rated burden).

 

Protection Winding

Optimized for protective relay systems, designed to maintain response fidelity and accuracy under heavy fault transient conditions.

 

Residual Voltage Winding (Broken-Delta)

Auxiliary secondary winding configured for earth-fault detection and ferroresonance damping in ungrounded or Petersen-coil-grounded networks.

 

 

 

Applications & Environmental Compatibility

Outdoor Substations & Switchyards: Feeds precise voltage data to control rooms for primary grid automation and monitoring.

 

Renewable Energy Step-Up Substations: Widely integrated into solar PV and wind farm collector substations.

 

Severe Environmental Conditions: Engineered for high altitudes, coastal salt-fog zones, and heavy industrial pollution by extending creepage distances up to Pollution Class IV per IEC 60815 guidelines.

JDZ(F)-35W2 Outdoor Single-phase Voltage Transformer

 

Technical Selection Guide

Insulation Coordination

Match equipment highest voltage (Um) and basic impulse insulation level (BIL) to local grid parameters and altitude derating factors per IEC 60071.

Burden & Metering Class Integration

Ensure total connected secondary burden (relays, meters, and wiring cables) remains strictly within the rated VA operating limits of the chosen accuracy class.

Ferroresonance Mitigation

For ungrounded networks prone to ferroresonant oscillations, specify auxiliary broken-delta windings with verified thermal ratings and damping provisions.

 

Mechanical Retrofitting & Footprint Matching

For substation upgrade or replacement projects, verify mounting flange bolt-hole pitch dimensions, terminal clearances, and enclosure protection ratings against existing structural steel frameworks.

 

JDZXW-35 Outdoor Single-phase Voltage Transformer

 

Manufacturing Process & Quality Control

APG Vacuum Casting: Automated Pressure Gelation chambers maintain strict thermal and vacuum (< 1 Torr) control to eliminate internal micro-voids and prevent partial discharge degradation under intense solar UV exposure.


Partial Discharge (PD) Screening: Routine testing conducted on 100% of production units inside electromagnetic shielding enclosures; apparent charge extinction threshold is strictly verified below 10 pC at 1.2 * Um / sqrt(3).


Dielectric & Error Verification: Power-frequency withstand tests, polarity checks, and automated bridge comparator error measurements (25%, 50%, 100% burden) executed with traceability to national calibration standards.


Hot-Dip Galvanizing: External mounting bases and support brackets treated with hot-dip galvanizing (min. 85 um coating thickness) complying with ISO 1461.


Export Maritime Packaging: Packed in fumigation-free, ISPM 15 compliant plywood crates with internal timber cradles, sealed within heavy-duty moisture barrier bags, and packed with active silica gel desiccants.

 

Customization & Engineering Support

 

 

We provide full technical customization for non-standard substation upgrades and replacement projects. Available tailoring parameters include:

Custom primary/secondary voltage ratios and multi-tap configurations

Non-standard mounting bracket dimensions and seismic-braced enclosures (IEEE 693 compliance)

Tailored creepage distances for extreme coastal or heavy industrial environments

Comprehensive submittal documentation packages including 2D/3D CAD drawings (STEP, PDF) and certified routine test reports

 

 

Frequently Asked Questions

 

 

Q: What information is required to select an outdoor voltage transformer?

A: Key parameters include system highest voltage (Um), primary/secondary voltage ratios, accuracy classes, rated burden, insulation levels, and site environmental conditions. For replacement projects, providing existing nameplate photos and mounting drawings ensures exact physical and electrical matching.

Q: Can outdoor voltage transformers be supplied with multiple secondary windings?

A: Yes. VTs can be configured with dual or triple secondary windings combining metering classes (0.2S), protection classes (3P), and auxiliary residual voltage (broken-delta) taps based on project specifications.

Q: What is the guaranteed partial discharge (PD) threshold?

A: All resin-insulated units undergo individual routine PD screening. Apparent charge values are certified to remain below 10 pC at 1.2 * Um / sqrt(3), guaranteeing long-term insulation reliability under continuous electric stress.

Q: Are Type Test Reports available from independent laboratories?

A: Yes. Full type test reports covering temperature rise, lightning impulse voltage withstand, short-time thermal current, and accuracy verification are available for review upon request.

Q: What is the standard manufacturing lead time?

A: Standard production lead time is 4 to 6 weeks following formal engineering drawing approval. Expedited production schedules can be arranged for emergency utility maintenance and replacement projects.

 

modular-1
Request a Technical Quotation

To receive a formal commercial and technical proposal within 24 hours, please submit your project specifications:

Electrical System: System Highest Voltage (Um), Primary & Secondary Voltage Ratios, System Grounding Type

Performance Requirements: Accuracy Class (0.2S, 0.5), Rated Burden (VA), Voltage Factor

Environmental Data: Site Altitude, Ambient Temperature Range, Pollution Level / Creepage Distance

Mechanical Constraints: Flange Bolt-Hole Pitch Dimensions, Quantity Required

Project Details: Destination Port, Target Delivery Date, and Applicable Standards (IEC / IEEE)

With abundant experience, Wenzhou Best Imp. & Exp. is one of the most professional outdoor voltage transformer manufacturers and suppliers in China. Please feel free to buy durable outdoor voltage transformer made in China here from our factory. Quality products and good service are available.

JDZ F 35W2 Outdoor Single phase Voltage Transformer, JDZXW 35 Outdoor Single phase Voltage Transformer, outdoor voltage transformer
Send Inquiry
Send Inquiry